Ring-sensors
The purpose of ring sensors from XECRO is to detect small metal parts with a static or dynamic functional principle. Static detection activates the output as long as an object is located in the sensing area (e.g. wire break detection). Dynamic detection means that the output is activated once an object entering the sensing area.
Due to the high resolution, a short response time, an adjustable impulse lengthening up to 150 ms, and a change-over switch to select normally closed or normally open function, XECRO ring sensors are suitable for general purposes. For optimal cable routing, the M12 male connector is mounted parallel or in a right angle to the wiring. They are protected against short circuit, polarity reversal, and overload.

Ring diameter | Operating Principle | Resolution |
---|---|---|
Ø 6.1 mm | static | > 1.0 mm |
Ø 6.1 mm | dynamic | > 0.5 mm |
Ø 10.1 mm | static | > 1.0 mm |
Ø 10.1 mm | dynamic | > 0.5 mm |
Ø 15.1 mm | static | > 2.0 mm |
Ø 15.1 mm | dynamic | > 0.8 mm |
Ø 21.1 mm | static | > 2.0 mm |
Ø 21.1 mm | dynamic | > 1.0 mm |
Features
Robust metal body
High sensing distances
Polarity reversal and short-circuit protected
LED status indication
Benefits
Minimal space requirements
Electrically fully protected
Common Specifications
Operating Voltage | 10 … 30 VDC |
Reverse Polarity Protection | built-in |
Output Load Capability | 200 mA |
Short Circuit Protection | built-in, self-resetting |
Voltage Drop | 1.5 V @ 200 mA |
Operating Temperature | –20 … 70°C | -4 … 158 °F |
Protection Class | IP67 |
Switching Indicator | yes, yellow |
Sensing Face Material | PBT |
Ring Material | PA 6.6 |